Diagnostic accuracy of perinatal post-mortem ultrasound (PMUS): a systematic review =================================================================================== * Susan Shelmerdine * Dean Langan * Neil J Sebire * Owen Arthurs ## Abstract **Objective** Ultrasound is ubiquitous in live paediatric imaging; however, its usage in post-mortem setting is less established. This systematic review aims to evaluate the diagnostic accuracy of paediatric post-mortem ultrasound (PMUS). **Design** MEDLINE, Embase and Cochrane Library databases were queried for studies published between 1998 and 2018 assessing PMUS diagnostic accuracy rates in children<18 years old, using autopsy as reference standard. Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies 2. A bivariate random-effects model was used to obtain combined mean estimates of sensitivity and specificity for different body systems. **Results** Four studies were included, all relating to ultrasound for perinatal deaths. The mean diagnostic sensitivity and specificity for neurological abnormalities were 84.3% (95% CI: 70.8% to 92.2%) and 96.7% (95% CI: 86.5% to 99.3%); for cardiothoracic abnormalities 52.1% (95% CI: 27.6% to 75.5%,) and 96.6% (95% CI: 86.8% to 99.2%); and for abdominal abnormalities 78.4% (95% CI: 61.0% to 89.4%) and 97.3% (95% CI: 88.9% to 99.4%). Combining all body systems, the mean sensitivity and specificity were 73.3% (95% CI: 59.9% to 83.5%) and 96.6% (95% CI: 92.6% to 98.4%). **Conclusions** PMUS demonstrates a reasonable diagnostic accuracy, particularly for abdominal and neurological abnormalities, although cardiac anomalies were less readily identified. **Trial registration number** CRD42018106968. * autopsy * minimally invasive autopsy * paediatric * perinatal * ultrasound * Autopsy * minimally invasive autopsy * paediatric * perinatal * ultrasound ### What is known about the subject? * Whole-body post-mortem ultrasound (PMUS) is being performed in several European centres for perinatal deaths. * Perinatal PMUS can be a useful alternative technique for non-invasive autopsy, where MRI is unavailable. ### What this study adds? * Perinatal PMUS provides a high diagnostic accuracy for neurological and abdominal pathologies. * Assessment of perinatal post-mortem cardiothoracic anomalies is challenging and less accurate. ## Introduction Post-mortem imaging techniques in children have gained popularity over the past decade, particularly given the decline in parental consent rates for invasive autopsy.1 2 Factors for this are multifaceted but include religious, emotional and communication barriers combined with the continued desire for further information to aid in future pregnancy management and bereavement counselling.3 The majority of studies relating to post-mortem imaging in children have related to post-mortem MRI (PMMR), with a recently published systematic review4 reporting sensitivity rates of 0.73 (95% CI: 0.56 to 0.84) in a pooled sample of 953 children across eight studies. For post-mortem CT imaging, there have been fewer studies in children compared with adults, with the majority reporting CT to be of lower yield in identification for the cause of death in non-suspicious (ie, ‘natural’ deaths) and perinatal losses,5–7 with a slight increase in benefit within a forensic setting.8 9 Ultrasound, while ubiquitous in live paediatric imaging, is far less established in the post-mortem setting. There are only a few articles either describing single site experience,10 or focussing on single anatomical areas such as congenital cardiac disorders.11 With rising costs, radiographer staffing shortages and reduced availability and access to MRI and CT imaging, ultrasound may play a key role in a future non-invasive post-mortem imaging service. The equipment is cheaper to acquire and run than cross-sectional imaging, with a variety of healthcare specialists already skilled in sonographic techniques (eg, fetal medicine clinicians, obstetricians, radiologists, sonographers). Nevertheless, without robust evidence detailing the diagnostic accuracy of this technique, it remains difficult to counsel parents appropriately and for clinicians to understand the benefit of this modality as a non-invasive imaging alternative to conventional autopsy. The aim of this systematic review is therefore to comprehensively assess the diagnostic accuracy of paediatric post-mortem ultrasonography (PMUS) from the existing literature. ## Materials and methods This study was registered in PROSPERO International prospective register of systematic reviews, CRD42018106968.12 Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines for transparent reporting of systematic reviews were followed.13 Ethical approval was not required for this retrospective review of published data. ### Patient involvement Patients were not directly involved in the design of this study. ### Literature review We searched MEDLINE (Ovid), EMBASE and the Cochrane Library databases for eligible articles published between 1 January 1998 and 31 December 2018 (20-year range), using database specific Boolean search strategies with terms and word variations relating to ‘autopsy’, ‘ultrasonography’ and ‘paediatrics’. The full search strategy was conducted in December 2018 (See online supplementary appendix S1 for details). A repeat search was conducted in July 2019 did not reveal any further eligible manuscripts for inclusion. ### Supplementary data [[bmjpo-2019-000566supp001.pdf]](pending:yes) ### Eligibility criteria Inclusion criteria encompassed work investigating diagnostic accuracy of post-mortem ultrasound (PMUS) imaging using autopsy as a reference standard. Studies were limited to human subjects, including fetuses (any gestation) and children (aged 0–18 years). No restrictions were placed on method of ultrasound technique, machine vendor and experience of operator or type of clinical setting. No language restrictions were used. Exclusion criteria included studies reported as conference abstracts, case reports, editorials, opinion articles, pictorial reviews, multimedia files (online videos, podcasts) and small case series (fewer than five cases). Articles without autopsy reference standard, or those relating to diagnostic accuracy for antenatal ultrasound imaging were excluded. All articles were independently searched by two reviewers (both paediatric radiologists with>8 years (SCS) and >12 years (OJA) experience). Abstracts of suitable studies were examined, and full papers were obtained. References from the retrieved full-text articles were manually examined for other possible publications. Disagreements were resolved by consensus. ### Data extraction and quantitative data synthesis Two reviewers (SCS and OJA) independently extracted data from the full articles into a database (Excel, Microsoft, Redmond WA, USA) which included the following factors: study design, study setting, population demographics, sample size, index test, study methodology, use of reference standard, diagnostic accuracy outcomes and measure of bias. Raw numbers of true and false positives and negative PMUS diagnoses were collected and inputted into a 2×2 table, considering autopsy as reference standard. Missing data were calculated if possible and, unpublished data or further information was obtained by contacting the authors. ### Methodological quality The quality and measure of bias for each included study was assessed by the modified Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria.14 Disagreements were resolved by consensus review of the literature. ### Statistical analysis Statistical analysis was performed by an experienced statistician (DL) using R.15 The available data were used to compute sensitivity and specificity for each study, with a 0.5 correction factor for studies with zero frequencies. A bivariate random-effects model was used to obtain combined mean estimates of sensitivity and specificity with 95% CIs for overall PMUS diagnosis and, by three body systems (neurological, cardiothoracic and abdominal). The functions *madad* and *reitsma* within the R package *mada* was used to synthesise the evidence. This bivariate approach takes into account the correlation between sensitivity and specificity when different threshold values are used for diagnosis in each study/body system.16 Summary receiver operating characteristic (SROC) curves were presented to show the relationship between the two outcomes. Spearman’s correlation coefficient (rho) was calculated to test for the presence of different thresholds. ## Results ### Eligible studies The initial search performed on 1 January 2019 yielded 6017 articles, after removal of duplicate studies. On the basis of study title and abstract, 5999 articles were excluded and 18 articles were retrieved in full text. After review of the full text, four studies were eventually included in the systematic review.17–20 A PRISMA flowchart is shown in figure 1. ![Figure 1](http://bmjpaedsopen.bmj.com/https://bmjpaedsopen.bmj.com/content/bmjpo/3/1/e000566/F1.medium.gif) [Figure 1](http://bmjpaedsopen.bmj.com/content/3/1/e000566/F1) Figure 1 Preferred Reporting Items for Systematic reviews and Meta-Analyses flow chart for the study search and selection. ### Patient population Our patient and study characteristics are provided in tables 1 and 2. All four articles related to PMUS for perinatal deaths.17–20 In all studies, parental consent was given for the ultrasound imaging. In total, 495 fetuses were imaged (sample size range: 75–169) and of these, 455 underwent an autopsy as a reference standard. The gestational ages ranged from 11 to 48 weeks. Most of the fetuses were the result of terminations of pregnancy (363/495, 73%), with 11% (52/495) miscarriages and 16% (80/495) intrauterine deaths. Gender mix was not reported in any of the studies. View this table: [Table 1](http://bmjpaedsopen.bmj.com/content/3/1/e000566/T1) Table 1 Demographic details of population studied for all articles View this table: [Table 2](http://bmjpaedsopen.bmj.com/content/3/1/e000566/T2) Table 2 Study characteristics for articles included in systematic review The majority of studies (3/4, 75%) were prospective in design and conducted in a single centre (3/4, 75%). Two studies originated from France,18 19 one study originated from Belgium20 and one was a multicentre study involving patients from two institutions, one in the UK and one in Belgium.17 The timeframe for data collection ranged between 1 and 4 years. ### Imaging assessment and operator Details regarding the index (PMUS) and reference (autopsy) tests in the studies of this systematic review are summarised in tables 3 and 4. View this table: [Table 3](http://bmjpaedsopen.bmj.com/content/3/1/e000566/T3) Table 3 Details of index test for studies included for systematic review View this table: [Table 4](http://bmjpaedsopen.bmj.com/content/3/1/e000566/T4) Table 4 Details of the reference test for studies included for systematic review A variety of ultrasound machine vendors and models were used. The most popular ultrasound machine was Voluson E8 (GE Medical Systems, Zipf, Austria), used by 3/5 (60%) centres. High-frequency linear probes were used by all operators, with 3/5 (60%) centres also using curvilinear or micro-convex ultrasound probes to acquire two-dimensional (2D) images. One study also acquired three-dimensional (3D) ultrasound volumes for head and body imaging in addition to standard 2D views.20 A single operator performed all PMUS studies in almost all centres, except for one centre (based in Belgium) for the study by Kang *et al*,17 where multiple operators performed the ultrasound scanning. For all cases, the ultrasound was performed prior to autopsy (therefore without knowledge of the reference test results). In two studies (2/4, 50%), the operators were blinded to the antenatal history,17 19 and in the remainder the antenatal results were known to the operator.18 20 The operator was frequently a paediatric radiologist (3/5, 60%) or fetal medicine specialist with ultrasound experience (2/5, 40%). ### Reference test For all studies, the reference standard was conventional autopsy. Only one study described a subset of patients (11/123, 9%) who underwent a minimally invasive autopsy by endoscopic examination,17 using a technique described by Sebire *et al*.21 All of the studies reported that their autopsies were performed according to national guidelines (ie, Royal College of Pathologists,22 23 SOFFoeT,24 French National Authority of Health).25 In one study, the autopsy guideline was not mentioned.18 All autopsies were performed by one of several pathologists within a department, rather than a single individual. The pathologists were aware of the clinical and antenatal history for all cases, and in three of the four studies the pathologists were blinded to the ultrasound results. ### Methodological quality assessment Using the QUADAS-2 tool, there was a moderate to high risk of bias concerning the ‘index text’ domain because the persons performing the ultrasound examination in two studies were aware of the patient’s antenatal history, and therefore could have been biassed when performing the examination.18 20 The risk of bias regarding the ‘flow and timing’ domain were unclear for two other studies since timing between ultrasound examination and autopsy were not defined.18 19 In one study,18 the risk of bias was unclear for both the patient selection and also reference standard, given that it was not stated how patients were recruited into the study or whether the autopsy results could have been biassed by the ultrasound findings. Assessment of bias regarding overall applicability concerns was low (figure 2). ![Figure 2](http://bmjpaedsopen.bmj.com/https://bmjpaedsopen.bmj.com/content/bmjpo/3/1/e000566/F2.medium.gif) [Figure 2](http://bmjpaedsopen.bmj.com/content/3/1/e000566/F2) Figure 2 Methodological quality assessment of the included studies using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Risk of bias and applicability concerns summary about each domain are shown for each included study. ### Diagnostic accuracy of ultrasound by body system The diagnostic accuracy rates for sensitivity and specificity of each body system are summarised in tables 5 and 6, with the results given in SROC plots in figures 3 and 4 for overall body diagnoses, and per body system, respectively. View this table: [Table 5](http://bmjpaedsopen.bmj.com/content/3/1/e000566/T5) Table 5 Estimated sensitivities and specificities of different body parts/systems from studies included in systematic review, with 95% CI in square brackets View this table: [Table 6](http://bmjpaedsopen.bmj.com/content/3/1/e000566/T6) Table 6 Estimates of mean sensitivity and specificity (with 95% CIs), overall and split by different body systems ![Figure 3](http://bmjpaedsopen.bmj.com/https://bmjpaedsopen.bmj.com/content/bmjpo/3/1/e000566/F3.medium.gif) [Figure 3](http://bmjpaedsopen.bmj.com/content/3/1/e000566/F3) Figure 3 Receiver operating characteristic plot of sensitivity against false positivity rate (1, specificity) of all 19 studies from table 5. Bivariate overall summary estimates of sensitivity and false positivity rate are overlaid with corresponding 95% confidence ellipses. SROC, Summary receiver operating characteristic. ![Figure 4](http://bmjpaedsopen.bmj.com/https://bmjpaedsopen.bmj.com/content/bmjpo/3/1/e000566/F4.medium.gif) [Figure 4](http://bmjpaedsopen.bmj.com/content/3/1/e000566/F4) Figure 4 Receiver operating characteristic plot of sensitivity against false positivity rate (1, specificity) of 19 studies from table 5 separated by body system. Bivariate overall summary estimates of sensitivity and false positivity rate for each body system are overlaid with corresponding 95% confidence ellipses. SROC, summary receiver operating characteristic Two studies did not explicitly state the non-diagnostic imaging or non-diagnostic autopsies rate.18 19 Kang *et al* 17 reported a non-diagnostic ultrasound result for 13/70 (18.6%) brain, 21/123 (17.1%) thoracic, 24/122 (19.7%) cardiac and 19/123 (15.4%) abdominal examinations. The non-diagnostic autopsy rate was 53/123 (43.1%) for the brain and 1/123 (0.8%) for the heart. Votino *et al* 20 reported non-diagnostic ultrasound imaging in 4/62 (6.5%) brain and 2/86 (2.3%) cardiothoracic ultrasound examinations. The non-diagnostic autopsy rate was 17/88 (19.3%) for the brain. In 5/88 (5.7%) cases, the brain was not examined at autopsy, only the body. Four studies were included in the bivariate meta-analysis model, all related to ultrasound usage in perinatal deaths. There was little evidence that studies had different thresholds for diagnosis (ie, negative correlation between sensitivity and specificity) (Spearman’s correlation (rho)=−0.310; 95% CI: −0.670 to 0.168). The mean diagnostic sensitivity and specificity, respectively (reported in table 6) was 84.3% (95% CI: 70.8% to 92.2%) and 96.7% (95% CI: 86.5% to 99.3%) for neurological abnormalities; 52.1% (95% CI: 27.6% to 75.5%) and 96.6% (95% CI: 86.8% to 99.2%) for cardiothoracic abnormalities and 78.4% (95% CI: 61.0% to 89.4%) and 97.3% (95% CI: 88.9% to 99.4%) for abdominal abnormalities. Combining all body systems, the mean sensitivity was 73.3% (95% CI: 59.9% to 83.5%) and the mean specificity was 96.6% (95% CI: 92.6% to 98.4%). Mean diagnostic sensitivity in the cardiothoracic body system was significantly lower than the neurological system (p=0.010) and marginally lower than the abdominal system, although non-significant at the 5% level (p=0.059). The study by Kang *et al* 1414 appeared to be an outlier compared with the other three studies, particularly for specificity rates of all body systems. When excluding this outlier the mean diagnostic sensitivity and specificity respectively was 87.4% (95% CI: 79.5% to 92.5%) and 97.9% (95% CI: 90.7% to 99.6%) for neurological abnormalities; 57.8% (95% CI: 24.1% to 85.6%) and 98.7% (95% CI: 94.5 to 99.7) for cardiothoracic abnormalities and 82.3% (95% CI: 63.8% to 92.5%) and 98.4% (95% CI: 94.5% to 99.5%) for abdominal abnormalities. Combining all body systems, the mean sensitivity was 78.8% (95% CI: 64.6% to 88.4%) and the mean specificity was 98.3% (95% CI: 96.3% to 99.2%). See online supplementary figures S2 and S3 for the SROC curves for overall diagnoses and by body system, with this study excluded. ## Discussion PMUS for perinatal deaths is a feasible technique, and currently performed in a few European centres. The diagnostic accuracy rates are highest for neurological and abdominal abnormalities (mean sensitivity rates of 84.3% and 78.4%, respectively), but less effective for cardiothoracic abnormalities (mean sensitivity rate of 52.1%). There were no studies reporting the PMUS accuracy rates in neonates and older children. The study raises two main potential clinical implications, first relating to improved parental choice and second potential healthcare cost savings. It is well known that parents report a high acceptability for non-invasive autopsy methods,3 26 27 and that many healthcare professionals also advocate post-mortem imaging techniques.28 Having another imaging modality available, such as ultrasound, would likely increase options for parental choice and their access to imaging. It may serve as a means for opening channels of communication between parents and clinicians, possibly reduce time spent grieving by offering a diagnosis and form of closure, or highlight the need for further counselling. As pregnant mothers will ubiquitously have been subject to fetal or antenatal ultrasound, they may have better inherent understanding of PMUS rather than cross-sectional imaging techniques. In terms of finances, a previous systematic review by Ahmad *et al* 4 described a potential cost saving with MRI virtopsy compared with invasive autopsy of approximately 33% (based on a full body MRI costing £226.34 and an autopsy costing £471.80, with a paediatric MRI virtopsy sensitivity rate of 73%). Using their same reference for costing,29 an ultrasound study taking approximately 20 min (costing £56 per case, with similar whole-body ultrasound pooled sensitivity rate of 74%) could offer even further benefits. Nevertheless, this calculation is based on assuming a similar rate of referral for invasive autopsy, which may be unlikely given the potential higher parental acceptability. Whether the balance between increased referrals and reduction in cost per patient would negate potential savings remains to be seen. The comparatively low PMUS sensitivity rates for cardiothoracic abnormalities is also important to recognise and may warrant alternative imaging with higher sensitivity (e,g, PMMR; 60%–82%).30 31 Whether detection of abnormalities with ultrasound will improve with operator experience, or is related to the technique itself is unknown. The lack of circulation and inability to use Doppler imaging on ultrasound, teamed with the presence of post-mortem intracardiac gas may hamper sonographic visualisation of cardiac structural abnormalities but 3D PMUS may possibly resolve some of these issues in future studies. In addition, PMUS operators may undergo a learning curve similar to that found for thoracic abnormalities using PMMR, with improvements in diagnostic accuracy from 30%–37% in early reports32 to 81.8%31 later. This may relate to better knowledge of normal post-mortem changes on imaging (ie, not overcalling pleural effusions as pathological) although infective pathologies still remain difficult to detect. In this systematic review, the majority of studies reported similar ultrasound diagnostic accuracy rates although those by Kang *et al* 17 were much lower, particularly for sensitivity rates of neurological and thoracic abnormalities and, specificity rates for all body systems. Reasons for this may relate to the fact that non-diagnostic ultrasound results were considered false negative for sensitivity calculation, and false positives for specificity calculations. In addition, the authors did report a high non-diagnostic ultrasound and autopsy rate for brain imaging of approximately 13/70 (18.6%) and for thoracic imaging of 21/123 (17.1%). While demographic details of the perinatal deaths in their study were similar to others, the high non-diagnostic rate may suggest a greater referral of macerated fetuses, which could have impeded ultrasound visualisation of certain organs and thus accurate diagnosis. There was also a laparoscopic-assisted minimally invasive autopsy as the reference standard in a subset of cases (11/123, 9%).21 While this technique has been shown to provide a high success rate in terms of tissue sampling and detection of histological abnormalities, the true diagnostic accuracy rate compared with conventional autopsy remains unknown.33 Despite these factors, we still include the results in our meta-analysis given that this was the only multicentre trial in our review and described results from more than one ultrasound operator, thereby providing potentially a more generalisable result for PMUS outcomes. There were several limitations to this study. The first relates to the generalisability of our results. There were very few studies assessing the diagnostic accuracy of PMUS in children, with all studies focussing on perinatal deaths, conducted within Europe, and with ultrasound examinations being performed by the same operator within each centre. The examinations were conducted within a few specialist centres focussing on this niche area, meaning they may represent an elevated level of accuracy, potentially not achievable if PMUS was to be offered in a more general clinical setting. The second limitation includes the classification and detection of abnormalities. In all cases, the pathologists performing the autopsies were not blinded to the antenatal history, and in one of the studies the ultrasound operator was also unblinded. There may have been a variation in the way PMUSs are performed and reported. For example, some operators may have considered ascites and pleural effusions as part of normal post-mortem change,34 35 while others may view these as significant abnormalities. There may also have been variation regarding the recording of non-diagnostic ultrasound examinations. In two studies, the number of non-diagnostic autopsies and ultrasound examinations were not reported,18 19 and it is not clear whether those ultrasound examinations were all of diagnostic quality, whether these were excluded prior to analysis, or whether the authors simply recorded these as ‘no abnormality’ where no significant findings were found, regardless of diagnostic quality. In the other two papers where non-diagnostic ultrasound examinations were reported, one excluded these from analysis,17 whereas the other considered them as an inaccurate finding (ie, recorded as ‘false positive’).20 Nevertheless despite such limitations, our work has several strengths. This paper represents the first systematic review on use of PMUS in perinatal deaths. It demonstrates a reasonable diagnostic accuracy for the majority of body systems and that it can be performed on a variety of scanner models, in a varied cohort of perinatal deaths across a range of gestational ages. Currently, there are no standardised protocols on how best to perform a PMUS study, nor for which situations in would be most beneficial in helping to change clinical management for future pregnancies. For example, it may have an apparent higher diagnostic rate in fetal demise for those pregnancies who have not yet undergone detailed second or third trimester antenatal ultrasound (ie, after 20 weeks gestation). Further research should be direct towards PMUS studies involving a larger cohort of perinatal deaths and also assessing usage in older children. There is clearly potential for this technique to be adopted in different clinical settings (such as in the developing world where pathological expertise is lacking but where causes of death are still important to confirm to inform global public health initiatives,36 by other specialists to increase appeal and availability following adequate training (eg, pathologists, obstetricians, sonographers) and international guidelines should be established for the appropriate indications for usage. There is also the ability for ultrasound to be used as a tool to aid percutaneous organ biopsies where tissue sampling is required to confirm histological diagnoses. In conclusion, this systematic review has provided evidence in showing that it is a feasible technique with a reasonable diagnostic accuracy when performed by experienced operators; however, further work will enable a better understanding of its place and purpose within a future non-invasive autopsy service. ## Footnotes * Contributors All authors listed in this manuscript fulfil the ICMJE recommendations for authorship. All authors provided substantial contribution to the conception and design of the work, analysis and interpretation; and drafting the work for intellectual content. All authors have had final approval for the version to be published and agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy are appropriately investigated and resolved. * Funding SCS is supported by a RCUK/ UKRI Innovation Fellowship and Medical Research Council (MRC) Clinical Research Training Fellowship (Grant Ref: MR/R00218/1). This award is jointly funded by the Royal College of Radiologists (RCR). OJA is funded by a National Institute for Health Research (NIHR) Career Development Fellowship (NIHR-CDF-2017-10-037), and NJS funded by an NIHR Senior Investigator award. The authors receive funding from the Great Ormond Street Children’s Charity and the Great Ormond Street Hospital NIHR Biomedical Research Centre. This article presents independent research funded by the MRC, RCR, NIHR and the views expressed are those of the author(s) and not necessarily those of the NHS, MRC, RCR, the NIHR or the Department of Health. * Competing interests None declared. * Patient consent for publication Not required. * Ethics approval Institutional review board approval was not required because it comprises a systematic review of published literature. * Provenance and peer review Not commissioned; externally peer reviewed. * Data availability statement Data are available upon reasonable request. All data relevant to the study are included in the article or uploaded as supplementary information. This is an open access article distributed in accordance with the Creative Commons Attribution 4.0 Unported (CC BY 4.0) license, which permits others to copy, redistribute, remix, transform and build upon this work for any purpose, provided the original work is properly cited, a link to the licence is given, and indication of whether changes were made. See: [https://creativecommons.org/licenses/by/4.0/](https://creativecommons.org/licenses/by/4.0/). ## References 1. Sieswerda-Hoogendoorn T , van Rijn RR . Current techniques in postmortem imaging with specific attention to paediatric applications. Pediatr Radiol 2010;40:141–52. quiz 259.[doi:10.1007/s00247-009-1486-0](http://dx.doi.org/10.1007/s00247-009-1486-0) [CrossRef](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=10.1007/s00247-009-1486-0&link_type=DOI) [PubMed](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=20013258&link_type=MED&atom=%2Fbmjpo%2F3%2F1%2Fe000566.atom) 2. Arthurs OJ , van Rijn RR , Sebire NJ . Current status of paediatric post-mortem imaging: an ESPR questionnaire-based survey. Pediatr Radiol 2014;44:244–51.[doi:10.1007/s00247-013-2827-6](http://dx.doi.org/10.1007/s00247-013-2827-6) [CrossRef](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=10.1007/s00247-013-2827-6&link_type=DOI) [PubMed](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=24276507&link_type=MED&atom=%2Fbmjpo%2F3%2F1%2Fe000566.atom) 3. Lewis C , Hill M , Arthurs OJ , et al . Factors affecting uptake of postmortem examination in the prenatal, perinatal and paediatric setting. BJOG 2018;125:172–81.[doi:10.1111/1471-0528.14600](http://dx.doi.org/10.1111/1471-0528.14600) 4. Ahmad MU , Sharif KA , Qayyum H , et al . Assessing the use of magnetic resonance imaging virtopsy as an alternative to autopsy: a systematic review and meta-analysis. Postgrad Med J 2017;93:671–8.[doi:10.1136/postgradmedj-2017-134945](http://dx.doi.org/10.1136/postgradmedj-2017-134945) [Abstract/FREE Full Text](http://bmjpaedsopen.bmj.com/lookup/ijlink/YTozOntzOjQ6InBhdGgiO3M6MTQ6Ii9sb29rdXAvaWpsaW5rIjtzOjU6InF1ZXJ5IjthOjQ6e3M6ODoibGlua1R5cGUiO3M6NDoiQUJTVCI7czoxMToiam91cm5hbENvZGUiO3M6MTI6InBvc3RncmFkbWVkaiI7czo1OiJyZXNpZCI7czoxMToiOTMvMTEwNS82NzEiO3M6NDoiYXRvbSI7czoyMzoiL2JtanBvLzMvMS9lMDAwNTY2LmF0b20iO31zOjg6ImZyYWdtZW50IjtzOjA6IiI7fQ==) 5. van Rijn RR , Beek EJ , van de Putte EM , et al . The value of postmortem computed tomography in paediatric natural cause of death: a Dutch observational study. Pediatr Radiol 2017;47:1514–22.[doi:10.1007/s00247-017-3911-0](http://dx.doi.org/10.1007/s00247-017-3911-0) 6. Arthurs OJ , Guy A , Thayyil S , et al . Comparison of diagnostic performance for perinatal and paediatric post-mortem imaging: CT versus MRI. Eur Radiol 2016;26:2327–36.[doi:10.1007/s00330-015-4057-9](http://dx.doi.org/10.1007/s00330-015-4057-9) 7. Oyake Y , Aoki T , Shiotani S , et al . Postmortem computed tomography for detecting causes of sudden death in infants and children: retrospective review of cases. Radiat Med 2006;24:493–502.[doi:10.1007/s11604-006-0061-y](http://dx.doi.org/10.1007/s11604-006-0061-y) [CrossRef](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=10.1007/s11604-006-0061-y&link_type=DOI) [PubMed](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=17058143&link_type=MED&atom=%2Fbmjpo%2F3%2F1%2Fe000566.atom) 8. Sieswerda-Hoogendoorn T , Soerdjbalie-Maikoe V , de Bakker H , et al . Postmortem CT compared to autopsy in children; concordance in a forensic setting. Int J Legal Med 2014;128:957–65.[doi:10.1007/s00414-014-0964-6](http://dx.doi.org/10.1007/s00414-014-0964-6) 9. Shelmerdine SC , Langan D , Hutchinson JC , et al . Chest radiographs versus CT for the detection of rib fractures in children (drift): a diagnostic accuracy observational study. Lancet Child Adolesc Health 2018;2:802–11.[doi:10.1016/S2352-4642(18)30274-8](http://dx.doi.org/10.1016/S2352-4642(18)30274-8) 10. Prodhomme O , Baud C , Saguintaah M , et al . Principles of fetal postmortem ultrasound: a personal review. J Forensic Radiol Imaging 2015;3:12–15.[doi:10.1016/j.jofri.2015.01.008](http://dx.doi.org/10.1016/j.jofri.2015.01.008) 11. Kumar M . Ultrasonography and autopsy correlation of fetal hypoplastic left heart syndrome. J Clin Ultrasound 2018;46:480–2.[doi:10.1002/jcu.22607](http://dx.doi.org/10.1002/jcu.22607) 12. Shelmerdine SC . Diagnostic accuracy of paediatric post-mortem ultrasound compared with autopsy: a systematic review. Available: [https://www.crd.york.ac.uk/prospero/display\_record.php?RecordID=106968](https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=106968) [Accessed 1 Sept 2018]. 13. Moher D , Liberati A , Tetzlaff J , et al . Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ 2009;339:b2535.[doi:10.1136/bmj.b2535](http://dx.doi.org/10.1136/bmj.b2535) 14. Whiting PF , Rutjes AWS , Westwood ME , et al . QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med 2011;155:529–36.[doi:10.7326/0003-4819-155-8-201110180-00009](http://dx.doi.org/10.7326/0003-4819-155-8-201110180-00009) [CrossRef](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=10.1059/0003-4819-155-8-201110180-00009&link_type=DOI) [PubMed](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=22007046&link_type=MED&atom=%2Fbmjpo%2F3%2F1%2Fe000566.atom) [Web of Science](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=000296066300018&link_type=ISI) 15. Team RC. R: a language and environment for statistical computing. Vienna, Austria: R Foundation for Statistical Computing, 2016. 16. Doebler P . Meta-Analysis of diagnostic accuracy with mada. R package version 0.5.9. Available: [www.r-forge.r-project.org/projects/mada/](http://www.r-forge.r-project.org/projects/mada/) 17. Kang X , Shelmerdine SC , Hurtado I , et al . Postmortem examination of human fetuses: comparison of two-dimensional ultrasound with invasive autopsy. Ultrasound Obstet Gynecol 2019;53:229–38.[doi:10.1002/uog.18828](http://dx.doi.org/10.1002/uog.18828) 18. Prodhomme O , Baud C , Saguintaah M , et al . Comparison of postmortem ultrasound and X-ray with autopsy in fetal death: retrospective study of 169 cases. J Forensic Radiol Imaging 2015;3:120–30.[doi:10.1016/j.jofri.2015.04.002](http://dx.doi.org/10.1016/j.jofri.2015.04.002) 19. Tuchtan L , Lesieur E , Bartoli C , et al . Diagnosis of congenital abnormalities with post-mortem ultrasound in perinatal death. Diagn Interv Imaging 2018;99:143–9.[doi:10.1016/j.diii.2017.11.005](http://dx.doi.org/10.1016/j.diii.2017.11.005) 20. Votino C , Cos Sanchez T , Bessieres B , et al . Minimally invasive fetal autopsy using ultrasound: a feasibility study. Ultrasound Obstet Gynecol 2018;52:776–83.[doi:10.1002/uog.14642](http://dx.doi.org/10.1002/uog.14642) 21. Sebire NJ , Weber MA , Thayyil S , et al . Minimally invasive perinatal autopsies using magnetic resonance imaging and endoscopic postmortem examination ("keyhole autopsy"): feasibility and initial experience. J Matern Fetal Neonatal Med 2012;25:513–8.[doi:10.3109/14767058.2011.601368](http://dx.doi.org/10.3109/14767058.2011.601368) [CrossRef](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=10.3109/14767058.2011.601368&link_type=DOI) [PubMed](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=21740313&link_type=MED&atom=%2Fbmjpo%2F3%2F1%2Fe000566.atom) 22. Royal College of Pathologists. Guidelines on autopsy practice: fetal autopsy (2nd trimester fetal loss and termination of pregnancy for congenital anomaly). Available: [www.rcpath.org](http://www.rcpath.org) [Accessed 16 May 2018]. 23. Royal College of Pathologists. Guidelines on autopsy practice: third trimester antepartum and intrapartum stillbirth. Available: [www.rcpath.org](http://www.rcpath.org) [Accessed 16 May 2018]. 24. Societe Francaise de Foetopathologie. Available: [http://soffoet.fr/page-d-exemple/la-foetopathologie/](http://soffoet.fr/page-d-exemple/la-foetopathologie/) [Accessed 09 Jan 2019]. 25. Haute Autorite de Sante. Available: [https://www.has-sante.fr/portail/jcms/r\_1455081/fr/home-page?portal=r\_1455081](https://www.has-sante.fr/portail/jcms/r_1455081/fr/home-page?portal=r_1455081) [Accessed 9 Jan 2019]. 26. Kang X , Cos T , Guizani M , et al . Parental acceptance of minimally invasive fetal and neonatal autopsy compared with conventional autopsy. Prenat Diagn 2014;34:1106–10.[doi:10.1002/pd.4435](http://dx.doi.org/10.1002/pd.4435) [CrossRef](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=10.1002/pd.4435&link_type=DOI) [PubMed](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=24933243&link_type=MED&atom=%2Fbmjpo%2F3%2F1%2Fe000566.atom) 27. Cannie M , Votino C , Moerman P , et al . Acceptance, reliability and confidence of diagnosis of fetal and neonatal virtuopsy compared with conventional autopsy: a prospective study. Ultrasound Obstet Gynecol 2012;39:659–65.[doi:10.1002/uog.10079](http://dx.doi.org/10.1002/uog.10079) [CrossRef](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=10.1002/uog.10079&link_type=DOI) [PubMed](http://bmjpaedsopen.bmj.com/lookup/external-ref?access_num=21919100&link_type=MED&atom=%2Fbmjpo%2F3%2F1%2Fe000566.atom) 28. Lewis C , Hill M , Arthurs OJ , et al . Health professionals' and coroners' views on less invasive perinatal and paediatric autopsy: a qualitative study. Arch Dis Child 2018;103:572–8.[doi:10.1136/archdischild-2017-314424](http://dx.doi.org/10.1136/archdischild-2017-314424) [Abstract/FREE Full Text](http://bmjpaedsopen.bmj.com/lookup/ijlink/YTozOntzOjQ6InBhdGgiO3M6MTQ6Ii9sb29rdXAvaWpsaW5rIjtzOjU6InF1ZXJ5IjthOjQ6e3M6ODoibGlua1R5cGUiO3M6NDoiQUJTVCI7czoxMToiam91cm5hbENvZGUiO3M6MTI6ImFyY2hkaXNjaGlsZCI7czo1OiJyZXNpZCI7czo5OiIxMDMvNi81NzIiO3M6NDoiYXRvbSI7czoyMzoiL2JtanBvLzMvMS9lMDAwNTY2LmF0b20iO31zOjg6ImZyYWdtZW50IjtzOjA6IiI7fQ==) 29. Nhs national tariff payment system 2016/17. Annex A. Available: [https://www.gov.uk/government/publications/nhs-national-tariff-payment-system-201617](https://www.gov.uk/government/publications/nhs-national-tariff-payment-system-201617) [Accessed 24 Jan 2019]. 30. Taylor AM , Sebire NJ , Ashworth MT , et al . Postmortem cardiovascular magnetic resonance imaging in fetuses and children: a masked comparison study with conventional autopsy. Circulation 2014;129:1937–44.[doi:10.1161/CIRCULATIONAHA.113.005641](http://dx.doi.org/10.1161/CIRCULATIONAHA.113.005641) [Abstract/FREE Full Text](http://bmjpaedsopen.bmj.com/lookup/ijlink/YTozOntzOjQ6InBhdGgiO3M6MTQ6Ii9sb29rdXAvaWpsaW5rIjtzOjU6InF1ZXJ5IjthOjQ6e3M6ODoibGlua1R5cGUiO3M6NDoiQUJTVCI7czoxMToiam91cm5hbENvZGUiO3M6MTQ6ImNpcmN1bGF0aW9uYWhhIjtzOjU6InJlc2lkIjtzOjExOiIxMjkvMTkvMTkzNyI7czo0OiJhdG9tIjtzOjIzOiIvYm1qcG8vMy8xL2UwMDA1NjYuYXRvbSI7fXM6ODoiZnJhZ21lbnQiO3M6MDoiIjt9) 31. Ashwin C , Hutchinson JC , Kang X , et al . Learning effect on perinatal post-mortem magnetic resonance imaging reporting: single reporter diagnostic accuracy of 200 cases. Prenat Diagn 2017;37:566–74.[doi:10.1002/pd.5043](http://dx.doi.org/10.1002/pd.5043) 32. Arthurs OJ , Thayyil S , Olsen OE , et al . Diagnostic accuracy of post-mortem MRI for thoracic abnormalities in fetuses and children. Eur Radiol 2014;24:2876–84.[doi:10.1007/s00330-014-3313-8](http://dx.doi.org/10.1007/s00330-014-3313-8) 33. Hutchinson C , Shelmerdine SC , Lewis C , et al . Feasibility and experience of the minimal procedure: minimally invasive perinatal and paediatric autopsies with laparoscopically assisted tissue sampling. Ultrasound Obstet Gynecol 2019. doi:[doi:10.1002/uog.20211](http://dx.doi.org/10.1002/uog.20211). [Epub ahead of print: 8 Jan 2019]. 34. Arthurs OJ , Barber JL , Taylor AM , et al . Normal perinatal and paediatric postmortem magnetic resonance imaging appearances. Pediatr Radiol 2015;45:527–35.[doi:10.1007/s00247-014-3166-y](http://dx.doi.org/10.1007/s00247-014-3166-y) 35. Barber JL , Hutchinson JC , Sebire NJ , et al . Pleural fluid accumulation detectable on paediatric post-mortem imaging: a possible marker of interval since death?. Int J Legal Med 2016;130:1003–10.[doi:10.1007/s00414-016-1320-9](http://dx.doi.org/10.1007/s00414-016-1320-9) 36. Menendez C , Castillo P , Martínez MJ , et al . Validity of a minimally invasive autopsy for cause of death determination in stillborn babies and neonates in Mozambique: an observational study. PLoS Med 2017;14:e1002318.[doi:10.1371/journal.pmed.1002318](http://dx.doi.org/10.1371/journal.pmed.1002318)